XCØ19 DBB Valve Manifold (ID=297)

The XC Double Block and Bleed valve is based on standard Ball, Needle, Ball configuration with a 1/2" NPT screwed vent (plugged). Available from 3/4" to 3" in size and pressure class from 150lbs to class 2500lbs available in 3 standard materials.

  • Connection Size: 3/4" - 3"
  • Pressure Rating: Class 150 - 2500 (API Optional)
  • Temperature Range: -46°C up to 200°C
  • Fire safe to ISO 10497
  • Fugitive emission tight ball valve design
  • Class A tight to the CO2 level between -29°C > 40°C at pressure of 431 bar (6250 psi) and below
  • Class B tight to the CO1 level between -46°C > 100°C at pressure of 431 bar (6250 psi) and below
  • API 6A PR2 qualified ball valve design at class 2500
  • Endurance tested to 1200 operational cycles at class 2500 in accordance with API 6A criteria
  • Type Approval Tested in accordance with SPE 77-300 at class 2500 + class 600 between +150°C and -29°C

Item NumberDescriptionMaterialQuantity
1 Bolt on Flange # 2
2 Stud * 12-16
3 Hex Nut * 12-16
4 O-Ring Endura V91A 2
5 Back-Up Ring Peek 2
6 Body A479 UNS S31803 2
7 Body Seal Graphite 2
8 1/2" NPT Blank Plug 1
9 Body Seal Graphite 2
10 Body # 1
11 Valve Handle (2) UNS S31600 2
12 Locking Pin UNS S31600 1
13 Locking Collar UNS S31600 1
14 Hex Cap Screw A4 ST/ST 1
15 Stop Pin UNS S31600 2
16 Extended "T" Handle UNS S31600 1
17 Packing Washer RTFE 2
18 Gland Packing Graphite 3
19 Bonnet Seal UNS S31600 1
20 Needle Valve Tip A479 UNS S31803 1
21 Needle Stem A479 UNS S31803 1
22 Dust Cap PVC 1
Item NumberDescriptionMaterialQuantity
23 Gland Adjuster UNS S31600 1
24 Gland Locknut UNS S31600 1
25 Bonnet Housing 1
26 SHC Screw A4 ST/ST 1
27 Locking Cam UNS S31600 1
28 Stem A479 UNS S31803 2
29 2.5mm Ball B446 UNS N06625 4
30 Anti-Static Spring Inconel X750 4
31 Back-up Ring Peek 2
32 O-Ring Endura V91A 2
33 Seat Peek 4
34 Ball B446 UNS N06625 2
35 Hex Nut A4 ST/ST 3
36 Belleville Washer ST/ST 5
37 Spacer UNS S31600 2
38 Anti-Extrusion Ring Peek 4
39 Gland Packing Graphite 4
40 Back-up Ring Peek 2
41 O-Ring Endura V91A 2

# = Body/Flange Material (S=F316, L=LF2, U=F51)* = Bolting Material (S&U=B8M/8MA, L=L7M/7M)✝ = 1/2" Vent Plug Material (S&L=A479 UNS S31600, U=A479 UNS S31803) ☨ = Bonnet Housing Material (S&L=A479 UNS S31600, U=A479 UNS S31803)


Products

RF/RTJ Flange x Flange/NPT

Flange Size (in.)Class RatingPart NumberA-RFA-RTJA 1/2" NPT-RFA 1/2" NPT-RTJØB-RFØB-RTJØCDE-RFE-RTJFNominal Mass
(in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.) (mm) (lbs.) (Kg)
3/4" 150 XC-19#-06AR☨06AR☨-B*-*** 11.46 291 N/A N/A 11.54 293 N/A N/A 1.69 42.9 N/A N/A 3.94 100 0.46 11.7 0.08 2.0 N/A N/A 3.82 97 22.05 10
3/4" 300 XC-19#-06BR☨06BR☨-B*-*** 12.01 305 12.40 315 11.81 300 12.01 305 1.69 42.9 2.50 63.6 4.53 115 0.58 14.8 0.08 2.0 0.25 6.4 3.82 97 24.25 11
3/4" 600 XC-19#-06CR☨06CR☨-B*-*** 12.56 319 12.48 317 12.09 307 12.05 306 1.69 42.9 2.50 63.6 4.53 115 0.65 16.4 0.28 7.0 0.25 6.4 3.82 97 26.46 12
3/4" 900/1500 XC-19#-06ER☨06ER☨-B*-*** 13.66 347 13.58 345 12.64 321 12.60 320 1.69 42.9 2.62 66.6 5.12 130 1.02 25.9 0.28 7.0 0.25 6.4 5.20 132 30.86 14
3/4" 2500 XC-19#-06FR☨06FR☨-B*-*** 13.74 349 13.74 349 12.68 322 12.68 322 1.69 42.9 2.88 73.1 5.51 140 1.27 32.3 0.28 7.0 0.25 6.4 5.20 132 35.27 16
1" 150 XC-19#-08AR☨08AR☨-B*-*** 11.61 295 11.93 303 11.61 295 11.77 299 2.00 50.8 2.50 63.6 4.33 110 0.48 12.2 0.08 2.0 0.25 6.4 3.82 97 24.25 11
1" 300 XC-19#-08BR☨08BR☨-B*-*** 12.17 309 12.48 317 11.89 302 12.05 306 2.00 50.8 2.76 70.1 4.92 125 0.65 16.4 0.08 2.0 0.25 6.4 5.20 132 26.46 12
1" 600 XC-19#-08CR☨08CR☨-B*-*** 12.64 321 12.64 321 12.13 308 12.13 308 2.00 50.8 2.76 70.1 4.92 125 0.71 18 0.28 7.0 0.25 6.4 5.20 132 28.66 13
1" 900/1500 XC-19#-08ER☨08ER☨-B*-*** 13.98 355 13.90 353 12.80 325 12.76 324 2.00 50.8 2.82 71.6 5.91 150 1.15 29.1 0.28 7.0 0.25 6.4 5.20 132 37.48 17
1" 2500 XC-19#-08FR☨08FR☨-B*-*** 14.06 357 14.06 357 12.83 326 12.83 326 2.00 50.8 3.25 82.6 6.30 160 1.40 35.5 0.28 7.0 0.25 6.4 5.20 132 44.09 20
1 1/2" 150 XC-19#-12AR☨12AR☨-B*-*** 11.46 291 11.77 299 11.54 293 11.69 297 2.87 73 3.25 82.6 4.92 125 0.65 16.4 0.08 2.0 0.25 6.4 5/20 132 26.46 12
1 1/2" 300 XC-19#-12BR☨12BR☨-B*-*** 12.17 309 12.48 317 11.89 302 12.05 306 2.87 73 3.57 90.6 6.10 155 0.77 19.6 0.08 2.0 0.25 6.4 5.20 132 33.07 15
1 1/2" 600 XC-19#-12CR☨12CR☨-B*-*** 12.56 319 12.56 319 12.09 307 12.09 307 2.87 73 3.57 90.6 6.10 155 0.90 22.8 0.28 7.0 0.25 6.4 5.20 132 35.27 16
1 1/2" 900/1500 XC-19#-12ER☨12ER☨-B*-*** 13.82 351 13.82 351 12.72 323 12.72 323 2.87 73 3.63 92.1 7.09 180 1.27 32.3 0.28 7.0 0.25 6.4 5.20 132 48.50 22
1 1/2" 2500 XC-19#-12FR☨12FR☨-B*-*** 14.53 369 14.61 371 13.07 332 13.11 333 2.87 73 4.49 114.1 8.07 205 1.77 45 0.28 7.0 0.31 7.9 6.57 167 68.34 31
2" 150 XC-19#-16AR☨16AR☨-B*-*** 11.30 287 11.69 297 11.46 291 11.65 296 3.63 92.1 4.02 102.1 5.91 150 0.71 18 0.08 2.0 0.25 6.4 5.20 132 30.86 14
2" 300 XC-19#-16BR☨16BR☨-B*-*** 11.61 295 12.09 307 11.61 295 11.85 301 3.63 92.1 4.26 108.1 6.50 165 0.83 21.2 0.08 2.0 0.31 7.9 5.20 132 35.27 16
2" 600 XC-19#-16CR☨16CR☨-B*-*** 12.40 315 12.48 317 12.01 305 12.05 306 3.63 92.1 4.26 108.1 6.50 165 1.02 25.9 0.28 7.0 0.31 7.9 5.20 132 39.68 18
2" 900/1500 XC-19#-16ER☨16ER☨-B*-*** 13.58 345 13.66 347 12.60 320 12.64 321 3.63 92.1 4.89 124.1 8.46 215 1.52 38.6 0.28 7.0 0.31 7.9 6.57 167 63.93 29
2" 2500 XC-19#-16FR☨16FR☨-B*-*** 14.29 363 14.37 365 12.95 329 12.99 330 3.63 92.1 5.24 133.1 9.25 235 2.02 51.4 0.28 7.0 0.31 7.9 6.57 167 90.39 41

# = Body/Flange Material (S=F316, L=LF2, U=F51)* = Bolting Material (2FC=L7M, 8ST=B8M)☨ = Flange Type (F=RF, J=RTJ)*** = Handle Options (SHO=Standard, HLK=Handle Lockable)

Flange x NPT
XC-19#-06AR☨##02-B*-***
XC-19#-06BR☨##02-B*-***

NPT configurations: please note part codes vary depending on the configuration of the valve, as shown above.## = NPT SIZE (04= 1/2", 06=3/4", 08=1", 10= 1 1/4")

SizeRFRTJ
1/4" -21 -21
1" +10 +10
1 1/4" +19 +19

In order to obtain overall length values (A) for 1 and 1 1/4" NPT connections, the values in the above table need to be added or subtracted from the overall length (A). For example, to calculate the overall length for an RF Flange x 1" female NPT, we add 10 to the 3/4" NPT - RF values in the main table.

Region:North America
Location of : United States: US: LooKupArray ( [userLocation] => US [userRegion] => North America )